IEC 60112 testing machine CTI index test device

Tracking Tester for Lab Testing EquipmentProduct details: Model ZLT-LDQ:The ZLT Tracking Tester is used for the determination of comparative tracking index  of solid electrical insulating materials on pieces taken from parts of electrical and electronic equipment and on plaques of material using alternating voltages.The ZLT

Featured Products

Tracking Tester for Lab Testing Equipment

Product details: Model ZLT-LDQ:

The ZLT Tracking Tester is used for the determination of comparative tracking index  of solid electrical insulating materials on pieces taken from parts of electrical and electronic equipment and on plaques of material using alternating voltages.
The ZLT Tracking Tester is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator. Inside the well lit cabinet, a test specimen is placed on a glass plate and two platinum electrodes are lowered onto the top surface. A gauge block is supplied with the instrument to ensure the electrodes have the proper distance between them. The table height is easily adjustable to ensure the proper angle of the electrodes and height of drops. The rest of the test is controlled from outside the test chamber with the door closed. The voltage, limiting current, drip rate and number of drips are all set on the control panel. An operator should observe the test to see if a flame ignites. The instrument sounds an alarm if there is a tracking failure of at least two seconds.
Platinum is specified as a material for the electrodes. The power supply unit is designed for voltages up to 600 V, or up to 1000V. An electronic control unit serves for releasing the drops.
In the case of the ZLT tracking tester, the electrode arrangement is mounted in a stainless steel cabinet. By a glass door, a good accessability of the testing arrangement ensurws a pleasant working. A safety system breaks the supply when the cabinet is opened.

Volume of chamber 0, 1 m3, model: ZLT-LDQ1
Volume of chamber 0, 5 m3, model: ZLT-LDQ2
Includes:
1 set of platinum electrodes 99% minimum purity,
1 bottle of ammonium chloride 99, 8% purity,
1 glass Platform,
1 scale, 4 mm,
Power  Supply220  V  50  Hz,   other  voltage  request
Power  Consumption650VA
Test  Voltage100~600V  continuonsly    adjustable,   displayed  value: r. m. s
Test  CurrentCurrent  limiting  1A± 0, 1A  adjustable,   displayed  value: r. m. s, tolerance  of  1, 5%
Electrode  Dimensionswidth:   5mm± 0, 1mm,   thickness:   2mm± 0, 1mm,   length  > 12mm,   one  end  chisel-edge  angle  :   30° ± 2° , platinum  with  a  purity  of  99%
Electrode  PressurePressure  force  exerted  on  the  specimen  by  each  electrode  1  N,   distance  between  electrodes  adjustable
Dripping  Nozzleouter  diameter:   0.9mm~1.2mm  for  solution  A
                  0.9mm~3.45mm  for  solution  B
Dripping  Interval0-99  seconds  (adjustable), the  time  for  50  drops  to  fall  on  the  specimen  shall  be  (24.5± 2)min
Height    Drops 35mm± 5mm
Dripping  WeightThe  mass  of  a  sequence  of  50  drops  shall  lie  between  0.997g  and  1.147g
The  mass  of  a  sequence  of  20  drops  shall  lie  between  0.380g  and  0.480g
Specimen  Support  PlatformThickness≥ 4mm  glass
Volume  Of  Chamber> 0.5m³ (or  0.1  m³ ),   black  interior
Outer  DimensionsW*D*H=1100mm*550mm*1100mm
Conform  to  standardIEC60112, IEC60335-1, IEC60598-1, IEC60884-1

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours